あなたは歯科・医療関係者ですか?

WHITE CROSSは、歯科・医療現場で働く方を対象に、良質な歯科医療情報の提供を目的とした会員制サイトです。

日本語AIでPubMedを検索

日本語AIでPubMedを検索

PubMedの提供する医学論文データベースを日本語で検索できます。AI(Deep Learning)を活用した機械翻訳エンジンにより、精度高く日本語へ翻訳された論文をご参照いただけます。
Niger J Clin Pract.2020 Mar;23(3):304-309. NigerJClinPract_2020_23_3_304_280029. doi: 10.4103/njcp.njcp_330_19.

異種重合義歯床アクリルレジンの色安定性に及ぼすコーヒー染色および義歯洗浄の影響

Effect of staining and denture cleaning on color stability of differently polymerized denture base acrylic resins.

  • E A Ayaz
  • S Ustun
PMID: 32134027 DOI: 10.4103/njcp.njcp_330_19.

抄録

背景:

歯垢や変色を除去し、口腔内の健康を維持し、義歯口内炎を予防するためには、義歯の衛生管理が重要な要素である。

Background: Denture hygiene is an important factor to remove dental plaque and discoloration, to provide optimal oral health, and to prevent denture stomatitis.

狙い目:

本研究の目的は,コーヒー染色および義歯洗浄剤が,重合度の異なる2種類の義歯床アクリル樹脂(熱およびマイクロ波)の色安定性に及ぼす影響をin vitroで評価することであった。

Aim: The purpose of this study was to evaluate the effect of coffee staining and denture cleaner on the color stability of two differently polymerized (heat and microwave) denture acrylic resin in vitro.

材料と方法:

本研究では,一般的に使用されている2種類の義歯床用アクリルレジンと,タブレット状の義歯洗浄剤を使用した.各アクリルレジンの円盤状試料をメーカーの指示に従って重合させた(n = 7).蒸留水(I)、義歯洗浄剤(II)、コーヒー(III)、コーヒー+義歯洗浄剤(IV)に浸漬する前後の色値をCIEDE2000色差式を用いてトリスチミュラス測色計で記録した。多重比較には、95%信頼水準(P<0.05)での二元分散分析(ANOVA)およびフィッシャーの最小有意差検定を用いた。浸漬前後のアクリルレジン義歯床試料の表面地形を500×倍率で撮影した.

Materials and Methods: Two commonly used denture base acrylic resins and effervesecnt tablet form denture cleaner were used in this study. Disc-shaped specimens from each acrylic resin were polymerized according to the manufacturer's instructions (n = 7). Color values were recorded before and after immersion in distilled water (I), denture cleaner (II), coffee (III), and coffee + denture cleaner (IV) with a tristimulus colorimeter using CIEDE2000 color difference formula. Two-way analysis of variance (ANOVA) and Fisher's least significant difference tests were used for multiple comparisons at a 95% confidence level (P < 0.05). Surface topography of the acrylic resin denture base specimens before and after immersion were taken under 500 × magnification.

結果:

双方向ANOVAにより,義歯床用樹脂と溶液との間に有意な相互作用が認められた(P < 0.001).義歯洗浄剤とコーヒー溶液に浸漬すると,アクリル樹脂義歯床の色が有意に変化した.

Results: The two-way ANOVA revealed significant interactions between denture base resins and solutions (P < 0.001). Immersion in denture cleaner and coffee solution caused significant color changes in acrylic resin denture bases.

結論:

熱とマイクロ波で重合されたアクリル義歯床用樹脂は色の安定性が異なることがある。コーヒーや義歯洗浄液に浸すと、色の変化が顕著になることがある。

Conclusion: Heat- and microwave-polymerized acrylic denture base resins can show different color stability. Immersion in coffee and denture cleaner solutions can cause noticeable color changes.